The effect of aberrations on objectively assessed image quality and depth of focus
2017
The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Comparison of two different devices to assess intraocular lenses
2016
[EN] In this paper, we have compared the performance of two commercial systems, Kaleo-I and IOLA Plus, in the characterization of monofocal intraocular lenses (IOLs) according to the International Standard requirements (ISO 11979-2). The dioptric power (DP) and the Modulation Transfer Function (MTF) at 100.1p/mm and 3.0 mm aperture have been measured with both instruments in twenty commercial monofocal HEMA IOLs and their agreement was assessed by Bland Altman analysis. Compared with the designed power, IOLA Plus gave lower values in 85% of measures: Kaleo I errors are dependent on the power of the lens: measurements were higher than the designed power in the low-medium power range and lowe…
Image quality with multifocal intraocular lenses and the effect of pupil size
2007
Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…
Imaging Quality of Bifocal Piggyback Intraocular Lens versus ReSTOR and TECNIS Multifocal Lenses
2009
Purpose The imaging quality provided by a piggyback integrated by a monofocal intraocular lens (IOL) + a bifocal IOL of zero power and +3.75 diopters of addition is compared with the optics quality of a simple multifocal IOL of the same power and addition. Methods The imaging quality was evaluated by determining the modulation transfer function (MTF), using an artificial eye simulating in vivo conditions of the anterior chamber, including an artificial cornea and a wet cell containing physiologic solution where the IOL was positioned. The MTFs of the bifocal piggyback for near and distance vision were measured, with pupil diameters of 3 and 5 mm, and compared with the MTFs of an equivalent …
Simple computation of the approximated modulation transfer function (MTF) using spreadsheet-software: method and evaluation in five maxillofacial CBC…
2019
OBJECTIVES: To develop a simple way to compute the approximated modulation transfer function (MTF) manually using conventional spreadsheet software. METHODS: Basing on an edge-image a method was developed, facilitating computation of the edge spread and line spread function in open-source spreadsheet software (Gnumeric; http://projects.gnome.org/gnumeric/downloads.shtml). By means of the integrated fast Fourier transformation Fourier coefficients are obtained from the line spread function which can then be plotted vs spatial frequency to obtain MTF-plots. For the experimental evaluation an edge test object was exposed in five commercial CBCT devices for maxillofacial applications. RESULTS: …
Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye
2020
[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…